«ALSENSE HPV» Kits

Detection of human papillomavirus DNA.

Designed for the detection and differential identification of human papillomavirus (HPV) DNA by real-time PCR.

  • Detection and differential identification of low- and high-risk HPV DNA (up to 22 genotypes, including 6, 11, 16, 18, 31, 33, 45).
  • Multiple kit configurations available depending on laboratory needs.
  • Limit of detection: 5–10 copies per reaction.
  • Built-in endogenous internal control.
  • Contain uracil-DNA glycosylase (UDG).
  • Automated PCR result analysis using dedicated software.
Application field: Medicine SKU: ALSENSE-HPV Category:

Description

PURPOSE

ALSENSE HPV reagent kits are designed for the detection and differential identification of human papillomavirus (HPV) DNA in nucleic acid extracts from various biological samples using real-time PCR (qPCR).

ALSENSE HPV kits provide a broad range of solutions for diverse laboratory diagnostic needs:

  • Detection of high-risk HPV types (including the most clinically significant genotypes 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68), associated with precancerous lesions and cervical cancer.
  • Detection of low-risk HPV types (6, 11, 42, 44), responsible for benign lesions.
  • Differential identification of key oncogenic types (16, 18, 45), essential for risk assessment and clinical decision-making.
  • Differential identification of high-risk HPV types and low-risk HPV types within a single kit.
  • Comprehensive panels for the detection of up to 22 clinically relevant HPV genotypes within a single kit.

The wide variety of ALSENSE HPV kit formats allows laboratories to choose the optimal solution — from basic screening to extended genotyping.

The reagent kits are compatible with Rotor-Gene Q/6000/3000 (QIAGEN GmbH), DT-96, DTprime, DTlite (DNA-Technology LLC), Bio-Rad CFX Opus 96, CFX96, iQ5, iCycler (Bio-Rad Laboratories, Inc.), Line-Gene 9600, 9660, QuantGene 9600 (Hangzhou Bioer Technology Co. Ltd), Gentier 96E, Gentier 96R (Xi’an Tianlong Science and Technology Co., Ltd), QuantStudio™ 3, QuantStudio™ 5 (Thermo Fisher Scientific), 7500 Real-Time PCR Systems (Applied Biosystems™), Mx 3005P™ QPCR System (Agilent), and equivalent models.

Please verify compatibility of the selected kit format with the PCR instrument used in your laboratory.

ASSAY PRINCIPLE

The principle of the reagent kit is based on real-time polymerase chain reaction (qPCR) with hybridization-fluorescence detection. The reaction mixture contains uracil-DNA glycosylase (UDG) to prevent contamination with amplification products. An endogenous internal control ensures monitoring of the reaction process for each sample.

BIOMATERIAL FOR ANALYSIS

  • epithelial cell swabs from the urogenital tract;
  • urine;
  • prostate secretion;
  • ejaculate;
  • biopsy material.

ADVANTAGES

  • limit of detection: 5–10 copies per reaction;
  • diagnostic sensitivity: 100% (99,5-100% CI);
  • diagnostic specificity: 100% (99,5-100% CI);
  • multiple kit formats available to suit different laboratory needs;
  • ready-to-use analysis protocols;
  • automated PCR result analysis using dedicated software.

Release form

Cat. Number Product name Note
Release Forms I, II, III, IV,,I,II (Plastic consumables are not included in the kit)
SH-103I-50 ALSENSE HPV I (designed for the detection of HPV DNA types 16 and 18) Kit for 50 samples
SH-103I-100 Kit for 100 samples
SH-103II-50 ALSENSE HPV II (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68) Kit for 50 samples
SH-103II-100 Kit for 100 samples
SH-103III-50 ALSENSE HPV III (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 with differential identification of types 16, 18, 45) Kit for 50 samples
SH-103III-100 Kit for 100 samples
SH-103IV-48 ALSENSE HPV IV (designed for the detection and differential identification of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68) Kit for 48 samples
SH-103IV-96 Kit for 96 samples
SH-103V-48 ALSENSE HPV (designed for the detection and differential identification of HPV DNA types 6, 11, 16, 18, 26, 31, 33, 35, 39, 42, 44, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73, 82) Kit for 48 samples
SH-103V-96 Kit for 96 samples
SH-103VI-50 ALSENSE HPVI (designed for the detection of LR HPV DNA types 6, 11 and HR HPV DNA types 16, 18) Kit for 50 samples
SH-103VI-100 Kit for 100 samples
SH-103VII-48 ALSENSE HPVII (designed for the detection of LR HPV DNA types 6, 11, 42, 44 and HR HPV DNA types 16, 18, 45) Kit for 48 samples
SH-103VII-96 Kit for 96 samples
Release Forms IS, IIS, IIIS,IS,IIS (PCR master mix in 8-well strips)
SH-103IS-48 ALSENSE HPV IS (designed for the detection of HPV DNA types 16 and 18) Kit for 48 samples
SH-103IS-96 Kit for 96 samples
SH-103IIS-48 ALSENSE HPV IIS (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68) Kit for 48 samples
SH-103IIS-96 Kit for 96 samples
SH-103IIIS-48 ALSENSE HPV IIIS (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 with differential identification of types 16, 18, 45) Kit for 48 samples
SH-103IIIS-96 Kit for 96 samples
SH-103VIS-48 ALSENSE HPVIS (designed for the detection of LR HPV DNA types 6, 11 and HR HPV DNA types 16, 18) Kit for 48 samples
SH-103VIS-96 Kit for 96 samples
SH-103VIIS-48 ALSENSE HPVIIS (designed for the detection of LR HPV DNA types 6, 11, 42, 44 and HR HPV DNA types 16, 18, 45) Kit for 48 samples
SH-103VIIS-96 Kit for 96 samples
Release Forms IP, IIP, IIIP, IVP,P,IP,IIP (PCR master mix in 96-well Plates)
SH-103IP-96 ALSENSE HPV IP (designed for the detection of HPV DNA types 16 and 18) Kit for 96 samples
SH-103IIP-96 ALSENSE HPV IIP (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68) Kit for 96 samples
SH-103IIIP-96 ALSENSE HPV IIIP (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 with differential identification of types 16, 18, 45) Kit for 96 samples
SH-103IVP-48 ALSENSE HPV IVP (designed for the detection and differential identification of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68) Kit for 48 samples
SH-103IVP-96 Kit for 96 samples
SH-103VP-48 ALSENSE HPVP (designed for the detection and differential identification of HPV DNA types 6, 11, 16, 18, 26, 31, 33, 35, 39, 42, 44, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73, 82) Kit for 48 samples
SH-103VP-96 Kit for 96 samples
SH-103VIP-96 ALSENSE HPVIP (designed for the detection of LR HPV DNA types 6, 11 and HR HPV DNA types 16, 18) Kit for 96 samples
SH-103VIIP-48 ALSENSE HPVIIP (designed for the detection of LR HPV DNA types 6, 11, 42, 44 and HR HPV DNA types 16, 18, 45) Kit for 48 samples
SH-103VIIP-96 Kit for 96 samples
Release Forms IPL, IIPL, IIIPL, IVPL,PL,IPL, IIPL (lyophilized PCR master mix in 96-well Plates)
SH-103IPL-96 ALSENSE HPV IPL (designed for the detection of HPV DNA types 16 and 18) Kit for 96 samples
SH-103IIPL-96 ALSENSE HPV IIPL (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68) Kit for 96 samples
SH-103IIIPL-96 ALSENSE HPV IIIPL (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 with differential identification of types 16, 18, 45) Kit for 96 samples
SH-103IVPL-48 ALSENSE HPV IVPL (designed for the detection and differential identification of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68) Kit for 48 samples
SH-103IVPL-96 Kit for 96 samples
SH-103VPL-48 ALSENSE HPVPL (designed for the detection and differential identification of HPV DNA types 6, 11, 16, 18, 26, 31, 33, 35, 39, 42, 44, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73, 82) Kit for 48 samples
SH-103VPL-96 Kit for 96 samples
SH-103VIPL-96 ALSENSE HPVIPL (designed for the detection of LR HPV DNA types 6, 11 and HR HPV DNA types 16, 18) Kit for 96 samples
SH-103VIIPL-48 ALSENSE HPVIIPL (designed for the detection of LR HPV DNA types 6, 11, 42, 44 and HR HPV DNA types 16, 18, 45) Kit for 48 samples
SH-103VIIPL-96 Kit for 96 samples
Release Forms IT, IIT, IIIT,IT (PCR master mix in Individual Tubes)
SH-103IT-50 ALSENSE HPV IT (designed for the detection of HPV DNA types 16 and 18) Kit for 50 samples
SH-103IT-100 Kit for 100 samples
SH-103IIT-50 ALSENSE HPV IIT (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68) Kit for 50 samples
SH-103IIT-100 Kit for 100 samples
SH-103IIIT-50 ALSENSE HPV IIIT (designed for the detection of HR HPV DNA types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 with differential identification of types 16, 18, 45) Kit for 50 samples
SH-103IIIT-100 Kit for 100 samples
SH-103VIT-50 ALSENSE HPVIT (designed for the detection of LR HPV DNA types 6, 11 and HR HPV DNA types 16, 18) Kit for 50 samples
SH-103VIT-100 Kit for 100 samples
We also recommend
РМ-103М-100 ALPREP Мах, release form М For manual nucleic acid extraction, 50 extractions
РМ-103A-96 ALPREP Мах, release form Auto For automated nucleic acid extraction, 96 extractions
РМ-103С-100 ALPREP Мах, release form С For manual nucleic acid extraction, 50 extractions
PМ-103.2 ALPREP Medium, release form 2 Transport medium 100 tubes of 0.5 ml each
PМ-103.4 ALPREP Medium, release form 4 Transport medium 1 bottle -- 55 ml 100 tubes (2 mlolume)
PF-103.4 ALPREP Fast, release form 4 Reagent for fast DNA extraction 1 bottle– 120 ml
PF-103.5 ALPREP Fast, release form 5 Reagent for fast DNA extraction 1 deep well plate 1 sealing film

Documentation

No available files.

Shopping cart

0
image/svg+xml

Ваша корзина пока пуста.

Continue Shopping

Присоединяйтесь к нашим Telegram-каналам! Отсканируйте QR-код или перейдите по ссылке ниже.

ALGIMED TECHNO

AlgimedTechno_official

NOVAprep

novaprep

Спасибо, что вы с нами!

Contact us