«ALFLOW Count» Fluorescent Microspheres

Direct determination of absolute cell counts in samples intended for flow cytometry analysis.

Designed for single-platform determination of absolute cell counts by flow cytometry.

  • Ready-to-use suspension of fluorescent microspheres.
  • Can be used with flow cytometers that are equipped with a blue laser or blue and red lasers.
Application field: Medicine, Science SKU: FС-032-50 | FС-032-100 | FС-032-200 | FC-108-50 | FC-108-100 | FC-108-200 Category:

Description

PURPOSE

«ALFLOW Count» Fluorescent Microspheres are a suspension of fluorescent polystyrene microbeads that have uniform size and fluorescence intensity. They are designed to determine absolute cell counts by flow cytometry. «ALFLOW Count» Fluorescent Microspheres can be used with flow cytometers equipped with a blue laser (488 nm) or blue and red lasers.

PRINCIPLE OF USE

Fluorescent microspheres are ready to use. No additional preparation is necessary. The principle of test depends upon mixing a known volume and concentration of ALFLOW Count Microspheres with an identical volume of a biological specimen. During the analysis on a flow cytometer, the absolute number (cells/μL) of cells in the sample can be determined by comparing cellular events to fluorescent microspheres events. Since the concentration of fluorescent microspheres is predetermined, the ratio of the number of cells to the number of microspheres can be determined and the absolute number of cells in the sample can be calculated.

Release form

Cat. Number Product name Note
FC-108-50 ALFLOW Count Fluorescent microspheres; 5 ml vial (50 tests)
FC-108-100 Fluorescent microspheres; 10 ml vial (100 tests)
FC-108-200 Fluorescent microspheres; 20 ml vial (200 tests)
We also recommend
FP-108M-100 ALFLOW Prep Multi Lysing reagent for manual lysis of red blood cells, 100 tests
FM-108T-100 ALFLOW MultiClone T Monoclonal antibodies reagent for the analysis of T-cells (1.1 ml vial, 100 tests)
FМ-108ТBNK-100 ALFLOW MultiClone TBNK Monoclonal antibodies reagent for the analysis of T-cells, B-cells, NK- and NKT-cells (1.1 ml vial, 100 tests)

Documentation

No available files.

Недавно просмотренные товары

  • Error image

    PCR master mix «ALZYME Color MIX»

    Ready-to-use 2x mix for PCR reactions with a dye for gel electrophoresis.

    Ready-to-use mix for PCR with dye for subsequent gel electrophoresis.

    • Direct loading of PCR products into the gel.
    • DNA polymerase resistant to PCR inhibitors.
    • Increased stability and specificity.
    • Protection against contamination (ALZYME Color MIX variant with UDG).
  • Error image

    Real-Time PCR master mix «ALZYME SYBR MIX»

    Ready-to-use 2X mix for PCR reactions with SYBR Green I dye.

    Ready-to-use mix for PCR with SYBR Green I.

    • DNA polymerase resistant to PCR inhibitors.
    • Increased stability and specificity.
    • Protection against contamination (ALZYME SYBR MIX variant with UDG).
  • Error image

    PCR master mix «ALZYME MIX»

    Ready-to-use 2X mix for PCR reactions.

    Ready-to-use mix for PCR.

    • DNA polymerase resistant to PCR inhibitors.
    • Increased stability and specificity.
    • Protection against contamination (ALZYME MIX with UDG).
  • Error image

    «ALZYME Elaine HSTaq» DNA polymerase

    Thermostable Hot-start Taq-polymerase.

    Thermostable hot-start DNA polymerase for direct PCR.

    • «Hot Start» technology avoids nonspecific amplification and enables room temperature reaction setup.
    • 5′ → 3′ exonuclease activity.
    • Resistance to PCR inhibitors.
    • Increased amplification rate.
    • Amplification of fragments for TA cloning.
  • Error image

    «ALZYME HSPfu» DNA polymerase

    Highly processive thermostable Hot-start Pfu-polymerase.

    A highly processive thermostable hot-start DNA polymerase.

    • «Hot Start» technology avoids nonspecific amplification and enables room temperature reaction setup.
    • 3’→5′ proofreading activity.
    • Devoid of 5’→3′ exonuclease activity.
    • Allows efficient amplification of DNA fragments up to 20000 bp.
    • Amplification of GC-rich sequences.
    • Resistance to PCR inhibitors.
  • Error image

    «ALFLOW Prep Fix» Fixative Solution

    Reagent for fixing cells in samples intended for flow cytometry analysis.

    Provides effective cell fixation during immunophenotyping procedure.

    • Preserves the prepared sample until measurement on a flow cytometer.
    • Variability of sample preparation: with or without washing.
  • Error image

    «ALFLOW Prep Multi» Lysing Reagent Kit

    Lysing Reagent Kit for manual erythrocyte lysis with a ready-to-use lysing reagent.

    Ready-to-use reagent kit for manual lysis of erythrocytes during preparation of human blood samples for analysis by flow cytometry.

    • Ready-to-use red blood cells lysing reagent.
    • Variability of sample preparation: with or without cells fixation, with or without washing.
    • «ALFLOW Prep Fix» Fixative Solution is included in the kit.
  • Error image

    «ALFLOW Prep 10Х» Lysing Reagent Kit

    Lysing Reagent Kit for manual erythrocyte lysis, with a 10-x concentrate of lysing reagent.

    Designed for manual lysis of erythrocytes during preparation of human blood samples for analysis by flow cytometry.

    • Consists of 10-х concentrate of lysing reagent and «ALFLOW Prep Fix» Fixative Solution.
    • Gentle lysis of red blood cells with minimal impact on leukocytes.
    • Variability of sample preparation: with or without cells fixation, with or without washing.
  • Error image

    «ALFLOW Isoton» Isotonic Solution

    Sheath fluid for flow cytometers.

    Ready-to-use isotonic buffer solution – Sheath Fluid for flow cytometers.

  • Набор реагентов «ALPREP Spin Blood»

    «ALPREP Spin Blood» Extraction kit

    DNA purification from blood samples by sorption on the spin-column membrane.

    Designed for manual DNA extraction from human and animal whole blood samples using the sorption method on a spin-column membrane.

    • Purity of extracted DNA is at least 1.8 by the A260/A280 ratio.
    • Nucleic acid yield is 2-10 µg.
    • Includes Proteinase K, which speeds up the lysis of complex matrices.
    • Ensures removal of PCR inhibitors and minimizes contamination risk.

Shopping cart

0
image/svg+xml

Ваша корзина пока пуста.

Continue Shopping