«ALMASS Neo» Reagent kits

Br

For the detection of newborn metabolic disorders by HPLC-MS/MS.

Designed for early screening of newborn’s metabolic disorders by quantitative determination of common amino acids, acylcarnitines, nucleosides, succinylacetone and lysophospholipids in peripheral blood samples.

  • Test for up to 57 analytes including 14 amino acids, 36 acylcarnitines, 2 nucleosides, succinylacetone and 4 lysophospholipids.
  • Ability to screen more than 30 forms of metabolic disorders of newborns.
  • The efficient and cost-effective way to expand newborn screening.
  • Suitable for mass screening.
Application field: Medicine, Science SKU: MN-019-480 | MN-019-960 | MN-019S-480 | MN-019S-960 | MN-019SA-480 | MN-019SA-960 | MN-019M-480 | MN-019M-960 Category:

Description

PURPOSE

«ALMASS Neo» Reagent kits are designed for quantitative determination of amino acids, acylcarnitines and adenosine in newborn’s peripheral blood samples on standard paper test blanks by tandem mass spectrometry without derivatization for the purpose of newborns screening for early detection of metabolic disorders.

Neonatal screening is the newborn screening program for the identification of genetic disorders. The procedure begins in the maternity hospital, where five drops of blood are drawn from the newborn, applying them to a special card, which is then dried. This produces a sample – a Dried Blood Spot (DBS) – which will be sent for further analysis. Abnormal marker analytes will indicate metabolic disorders and allow the identification of potentially sick newborns. The panel of analytes is represented by amino acids, acylcarnitines, nucleosides, succinylacetone and lysophospholipids. Screening is not literally an «assay by which a diagnosis can be made quickly». Further examinations and additional tests should be performed by medical specialists.

TEST PRINCIPLE

The analysis is performed by tandem mass spectrometry, with the triple quadrupole being the best instrument here. When working with a kit without a derivatizing agent, a mixture of isotope-labeled internal standards is used. The operator adds them at the earliest stage, and after sample preparation puts them into the autosampler of the instrument. The analysis is done without a column, by Flow Injection. The mobile phase picks up the injected volume, and the moment the mixture enters the detector, the flow is abruptly dumped and pulled by a slow current. The absence of a column greatly reduces the analysis time. With proper setup and timely maintenance of the instrument, the technique is simple and quick.

So, the detection of analytes using ALMASS Neo reagent kit includes the following steps:

  • extraction of analytes from dried blood spots (DBS) with a solution containing stable isotope labelled internal standards;
  • analysis using non-derivatized MSMS;
  • quantification of the result relative to the response of the corresponding internal standard of known concentration.

PANEL OF ANALYTES

Analyte Internal standards Control samples
Amino acids
Ala 2H3-Ala Ala
Arg 13C6-Arg Arg
Asa 13C6-Arg Asa
Cit 2H2-Cit Cit
Gln/Lys 13C5-Gln Gln
Glu 13C5-Gln Gln
Gly 13C2,15N -Gly Gly
Leu/Ile/Pro-OH 2H3-Leu Leu
Met 2H3-Met Met
Orn 2H2-Orn Orn
Phe 13C6-Phe Phe
Pro 13C5-Pro Pro
Tyr 13C6-Tyr Tyr
Val 13C5-Val Val
Acylcarnitines
C0 2H3-C0 C0
C2 2H3-C2 C2
C3 2H3-C3 C3
C3DC/C4OH 2H3-C4 C4
C4 2H3-C4 C4
C4DC/C5OH 2H3-C5 C5
C5 2H3-C5 C5
C5:1 2H3-C5 C5
С5DC/C6OH 2H3,13C-C5DC С5DC
C6 2H3-C6 C6
C6DC 2H3,13C-C5DC С5DC
C8 2H3-C8 C8
C8:1 2H3-C8 C8
C10 2H3-C10 C10
C10:1 2H3-C10 C10
C10:2 2H3-C10 C10
C12 2H3-C12 C12
C12:1 2H3-C12 C12
C14 2H3-C14 C14
C14:1 2H3-C14 C14
C14:2 2H3-C14 C14
C14OH 2H3-C14 C14
C16 2H3-C16 C16
C16:1 2H3-C16 C16
C16OH 2H3-C16 C16
C16:1OH/C17 2H3-C16 C16
C18 2H3-C18 C18
C18:1 2H3-C18 C18
C18:2 2H3-C18 C18
C18OH 2H3-C18 C18
C18:1OH 2H3-C18 C18
C18:2OH 2H3-C18 C18
C20 2H9-C26 C26
C22 2H9-C26 C26
C24 2H9-C26 C26
C26 2H9-C26 C26
Ketones
SA 13С5-SA SA
Nucleosides
ADO 13C5-ADO ADO
D-ADO 13C5-ADO ADO
Lysophospholipids
C20:0-LPC 2H4-C26:0-LPC C26:0-LPC
C22:0-LPC 2H4-C26:0-LPC C26:0-LPC
C24:0-LPC 2H4-C26:0-LPC C26:0-LPC
C26:0-LPC 2H4-C26:0-LPC C26:0-LPC

BENEFITS

  • simultaneous identification of 57 analytes: 14 amino acids, 36 acylcarnitines, 2 nucleosides, succinylacetone and 4 lysophospholipids;
  • ability to screen more than 30 forms of metabolic disorders of newborns;
  • suitable for mass screening due to shorter analysis time and the use of a Flow Injection method;
  • efficient and cost-effective way to expand newborn screening;
  • optional reagents including non-derivatized assay solutions and succinylacetone assay solution.

Release form

«ALMASS Neo» Reagent kits is available in 8 versions.

Cat. Number Product name Note
MN-019-480 ALMASS Neo Start For 480 tests
MN-019-960 For 960 tests
MN-019S-480 ALMASS Neo Start S For 480 tests; includes flow solvent and extraction solution
MN-019S-960 For 960 tests; includes flow solvent and extraction solution
MN-019SA-480 ALMASS Neo Start SA For 480 tests; includes reagent for the detection of succinylacetone
MN-019SA-960 For 960 tests; includes reagent for the detection of succinylacetone
MN-019M-480 ALMASS Neo Max For 480 tests; includes flow solvent, extraction solution and reagent for the detection of succinylacetone
MN-019M-960 For 960 tests; includes flow solvent, extraction solution and reagent for the detection of succinylacetone
We also recommend
MN-020S-480 «ALMASS Neo S» Assay solutions For 480 tests
MN-020S-960 For 960 tests
MN-028SA-480 «ALMASS Neo SA» reagent For 480 tests
MN-028SA-960 For 960 tests
MB-021S-9000 ALMASS Bio Standart kit «ALMASS Bio Solvent» reagent - 1,2 ml x 1ial. «ALMASS Bio Standart» reagent - 1 mg x 3 tubes.
MB-021M-9000 ALMASS Bio Matrix kit «ALMASS Bio Solvent» reagent - 1,2 ml x 9ials; «ALMASS Bio Matrix» reagent - 15 mg x 9 tubes.

Documentation